Error Code E CO
Communication error between Main MICOM and Display MICOM
Moderate
Address soon - your appliance may not work properly
How to Fix
- 1
Check all harness connections between main PCB and display PCB for looseness, especially hinge wiring.
- 2
Check voltage at CON101 pins 18–16; expected 12V. If not 12V, check hinge wiring (loose connection). If hinge is OK but voltage is wrong, replace Main PCB.
- 3
Check voltage at CON101 pins 10–16; expected 5V. If not 5V, check hinge connection. If hinge OK, replace Main PCB.
- 4
Check voltage at CON101 pins 14–16; expected 0V or 5V (not between). If not correct, replace Display PCB.
- 5
Check voltage at CON101 pins 12–16; expected 0V or 5V. If not correct, replace Main PCB.
- 6
Check voltage at CON5 pins 4–3; expected 0V or 5V. If not correct, replace Display PCB.
- 7
Check voltage at CON5 pins 5–3; expected 0V or 5V. If not correct, replace Main PCB.
- 8
If all checks are within spec, explain to customer.
This Error Applies To
LG LL31H6530S Series Refrigerators
Related Error Codes
Freezer cubed ice maker kit defect
Cubed Mini ice maker kit defect
Flow meter defect / lack of water supply
Craft ice maker error (cloudy ice / harvest heater failure)
Freezer sensor defect
Refrigerator sensor defect
Pantry/Auto-pantry sensor defect
Ice maker kit (in-door) defect